Category: HPLC Columns FAQ
/
/
/
Aqueous Normal Phase ANP ballistic gradients compared to same in HILIC - Tips & Suggestions
Read More
Aqueous Normal Phase ANP solvent strength order - FAQ
Read More
Aqueous Normal Phase defined & compared to Reversed Phase & Normal Phase definitions HPLC - Tech Information
Read More
Are 10um pore size available in the Cogent Column Filters - FAQ
Read More
Are Cogent 2.o HPLC columns compatible with Agilent 1290 Infinity II instruments - FAQ
Read More
Are stainless steel tubing or fittings autoclavable - FAQ
Read More
Are there HPLC columns that could be used to separate both polar and nonpolar compounds in a single run - FAQ
Read More
Assembly Instructions for Guard Column Holder - Tech Information
Read More
Biological extracts Diamond Hydride columns and LCMS ion source diminished peak height problem - FAQ
Read More
Calculate the ligand density of a bonded phase of an HPLC column - How To
Read More
Calculating theoretical plates N at half height - How To
Read More
Can Aqueous Normal Phase ANP methods be used to separate steroids - FAQ
Read More
Can I backflush the Cogent column filter for longer in-service life - FAQ
Read More
Can I change the filter element in the Cogent Column Filters - FAQ
Read More
Can I use a silica or Silica-C guard column with an analytical column of a different phase - FAQ
Read More
Can I use of the Cogent Diamond Hydride HPLC column above pH 7 in HPLC - FAQ
Read More
Can I use the Chemical Solutions HSQ Kit with the longer column from the original PQ Kit - FAQ
Read More
Can I use triethylamine TEA with Cogent Diamond Hydride columns - FAQ
Read More
Can Reversed Phase and ANP mechanisms operate with the same effect at the same time - FAQ
Read More
Can the Cogent Column Filters replace my HPLC guard columns - FAQ
Read More
Causes of an HPLC column appearing to lack sensitivity in LCMS - Tips & Suggestions
Read More
Changing column ID means changing your gradient - Tips & Suggestions
Read More
Choose an appropriate guard column when using a Cogent TYPE-C HPLC column - How To
Read More
Choosing the correct HPLC column coupler - How To
Read More
Citric acid retention and peak shape has changed compared to data from a previous run what happened - FAQ
Read More
Cogent TYPE-C columns used in prep chromatography offer value - Tips & Suggestions
Read More
Common cause of excessive back pressure in HPLC columns - FAQ
Read More
Converting Cogent TYPE-C columns to normal phase after use in reversed phase - How To
Read More
Cysteine analysis tips for LCMS - Tips & Suggestions
Read More
Determine pore volume of an HPLC column using HPLC injections - How To
Read More
Determining efficiency of HPLC methods 4um v 2um - FAQ
Read More
Determining HPLC method accuracy - How To
Read More
Do all PEEK HPLC fittings fit all receiving ports - FAQ
Read More
Do Cogent TYPE-C Silica columns have a partial positive charge and if so is retention for basic compounds reduced because of this - Tech Information
Read More
Do I need any special fittings to use the Cogent Column Filter with my current HPLC column - FAQ
Read More
Do Partisil HPLC columns need an extra end fitting kit - FAQ
Read More
Do the Cogent Silica-C columns contain any carbon - FAQ
Read More
Does the Hichrom brand column coupler work with the Partisil and Partisphere HPLC columns - FAQ
Read More
Eliminate high background noise using a new Cogent HPLC column - Tips & Suggestions
Read More
Eliminating shoulder peaks in an HPLC method using Cogent RP C18 columns - Tips & Suggestions
Read More
For the separation of polar intermediates in reversed phase HPLC which C18 column do you recommend - FAQ
Read More
Frits smaller than 0.062 inches OD cannot be chamfered - Tech Information
Read More
Guidelines for packing in the PEEK column hardware - Tips & Suggestions
Read More
Helpful HPLC columns you may not know about - White Paper
Read More
How can Cogent TYPE-C HPLC columns offer faster results compared to other type of silica based columns - FAQ
Read More
How can I fix split peaks with high back pressure in HPLC analyses - FAQ
Read More
How can I separate capsaicinoids in hot sauce by HPLC - Tips & Suggestions
Read More
How can I separate methacrylic acid and dodecyl benzene sulfonic acid - FAQ
Read More
How do I connect a guard column to an analytical column - FAQ
Read More
How do the terms nano capillary and micro LC differ in terms of column ID and typical flow rates - FAQ
Read More
How does efficiency in Aqueous Normal Phase ANP compare to HILIC in HPLC - FAQ
Read More
How does the shorter column supplied in the HSQ kit affect the data compared to the longer column from the PQ Kit - FAQ
Read More
How often do I need to clean or wash a Cogent TYPE-C column to keep data precise - FAQ
Read More
How often do I need to do the conditioning procedure for a new Diamond Hydride column - FAQ
Read More
How to back flush and wash an HPLC column for reuse - Tips & Suggestions
Read More
How to condition Cogent RP or HPS or Axis HPLC columns for storage - Tips & Suggestions
Read More
How to get improved retention and peak shape for glutamine glutamic acid and aspartic acid - Tips & Suggestions
Read More
How to keep HPLC columns free of adsorbed contaminants - How To
Read More
How to minimize HPLC column blockage from most common causes - Tips & Suggestions
Read More
HPLC Retention time shift troubleshooting - Tips & Suggestions
Read More
HPLC stationary phase can be responsible for a blocked frit- Tips & Suggestions
Read More
I heard that there is not a good alternative to HILIC to achieve sufficient retention for some compounds - FAQ
Read More
I see a strange saw tooth type of pattern in the UV baseline using my Cogent HPLC column what is it and how can I fix it - FAQ
Read More
Improvement in signal to noise in LCMS with an ANP method - Tips & Suggestions
Read More
Is the Cogent Column Filter compatible with a 2.1mm ID column - FAQ
Read More
Know the void volume of an HPLC column - Tips & Suggestions
Read More
Method development tip for maleic hydrazide - Tips & Suggestions
Read More
Mobile Phase recommendation Cogent Diamond Hydride columns for use with serum samples in Aqueous Normal Phase LCMS - Tips & Suggestions
Read More
Negative Baselines in HPLC at 214nm - Tips & Suggestions
Read More
NMR structure confirmation data for Cogent Bidentate C18 phases - Tech Information
Read More
NMR structure confirmation data for Cogent UDC-cholesterol phases - Tech Information
Read More
PEEK slurry reservoir 2.1mm ID column packing hardware information - FAQ
Read More
Percentage of acid needed in Aqueous Normal Phase ANP methods - Tips & Suggestions
Read More
Policy on verifying a new Cogent HPLC column performance - Tips & Suggestions
Read More
Protecting HPLC analytical columns and when to use guard columns vs Cogent Column Filters - Tips & Suggestions
Read More
Random shifting of retention times in HPLC chromatograms - Tips & Suggestions
Read More
Reasons for using direct adaptive Di-Ad HPLC column connectors - Tips & Suggestions
Read More
Retention and or peak shape for citric acid has changed compared to data from a previous HPLC run - Tips & Suggestions
Read More
Ribose and Xylose analysis without forming Schiff bases - AppNote
Read More
Sample concentration changes can effect retention time in HPLC - Primer
Read More
Should I filter my HPLC solvents and buffers before use - FAQ
Read More
Should I use a 1 piece fitting or a 2 piece fitting for HPLC - FAQ
Read More
Since Cogent TYPE-C columns can be used in Reversed Phase or Normal Phase what do you suggest to switch these solvent systems which are not miscible - FAQ
Read More
Since Cogent TYPE-C Silica columns use a transition metal catalyst in production what is the presence of any trace quantity on the surface of the stationary phase- FAQ
Read More
Solvents and solutions that should be avoided when using PEEK filters fittings or tubing - Tech Information
Read More
Solving baseline problems in Aqueous Normal Phase ANP methods - Tips & Suggestions
Read More
The common names of HPLC column diameters - Primer
Read More
The effect of ionic strength of the mobile phase additive for HPLC columns in Aqueous Normal Phase - Tips & Suggestions
Read More
Theoretical plate estimates indicates column condition - Primer
Read More
Using an Aqueous Normal Phase ANP method will sodium ions interfere with succinate when analyzing sodium succinate - FAQ
Read More
Using Aqueous Normal Phase ANP to your advantage - White Paper
Read More
Using temperature changes for separations of terpenoids with the Cogent Bidentate C18 and UDC-Cholesterol HPLC columns - Tips & Suggestions
Read More
What are some notable examples of journal articles that feature Aqueous Normal Phase ANP methods in metabolomics studies - FAQ
Read More
What are the dimensions of 4.6mm ID 5um frits for columns made with PEEK - FAQ
Read More
What are the main differences between Cogent Amide columns and other brands of Amide - FAQ
Read More
What are the thread specifications for the PEEK columns - FAQ
Read More
What are the typical flow rates recommended by HPLC column companies to start with for various column ID - Primer
Read More
What are the uses of PEEK HPLC column hardware - FAQ
Read More
What are theoretical plates and HETP in HPLC - Primer
Read More
What column changes are permitted in USP HPLC methods - FAQ
Read More
What does stainless in stainless steel mean - FAQ
Read More
What does the term 10-32 mean to a chromatographer working with HPLC vials - FAQ
Read More
What is a direct silicon to carbon bond regarding Cogent HPLC columns - FAQ
Read More
What is a Master Batch for Cogent HPLC columns - FAQ
Read More
What is the cause of a pressure increase after injections of blanks in HPLC - FAQ
Read More
What is the chemical structure of the ligand in the Cogent DIOL HPLC stationary phase - FAQ
Read More
What is the compatibility of Cogent TYPE-C Silica HPLC columns with UHPLC instruments - FAQ
Read More
What is the definition of a fitting for HPLC - FAQ
Read More
What is the definition of passivating and purging in HPLC - FAQ
Read More
What is the difference between a 4um and a 5um particle in a C18 column - FAQ
Read More
What is the difference between a Waters type fitting and a standard 10-32 fitting - FAQ
Read More
What is the difference between ferrules made of stainless steel vs stainless steel and PEEK hybrids - FAQ
Read More
What is the difference between the ColumnStore 120 and four ColumnStore 30 - FAQ
Read More
What Is the Difference Between Weak and Strong Cation Exchange in Ion Exchange Chromatography - FAQ
Read More
What is the maximum pressure Cogent HPLC columns can tolerate - FAQ
Read More
What is the maximum pressure of the 2.1mm PEEK HPLC columns - FAQ
Read More
What is the maximum pressure of your guard columns - FAQ
Read More
What is the maximum pressure rating for Cogent HPLC columns? - FAQ
Read More
What is the maximum pressure the Cogent Column Filters should be used with - FAQ
Read More
What is the maximum temperature for Cogent Diamond Hydride HPLC columns - FAQ
Read More
What is the pH range of 316 stainless steel laboratory tubing fittings and sparging stones - FAQ
Read More
What is the pilot length or dimension X depth for end fittings uses to connect HPLC columns - FAQ
Read More
What is the pressure rating of the Hichrom brand column coupler - FAQ
Read More
What is the purpose of back flushing an HPLC column and will it damage it - FAQ
Read More
What is the purpose of using isopropanol IPA as part of the mobile phase solvent in ANP methods - FAQ
Read More
What is the thickness of the SS filter element in the Cogent Column Filters - FAQ
Read More
What is the useful temperature range of 316 stainless steel laboratory products - FAQ
Read More
What is the useful temperature range of PEEK laboratory products - FAQ
Read More
What is the volume of Cogent HPLC columns - FAQ
Read More
What materials are the Cogent Column Filters manufactured with - FAQ
Read More
What results when I use a small guard column with a larger ID or prep column - FAQ
Read More
What type of fitting is best to use with the Cogent HPLC and LCMS columns - FAQ
Read More
What type of tubing do I use to connect the guard column holder to analytical columns - FAQ
Read More
When is the acid group of the Cogent UDA HPLC column ionized - Tech Information
Read More
Which columns are compatible with the Hichrom brand column coupler Cat No 47450-06 - FAQ
Read More
Which ferrules are best when using soft polymeric tubing - FAQ
Read More
Which HPLC column do you suggest for analysis of carotene or lycopene - FAQ
Read More
Which HPLC column ID dimensions are the Hichrom brand guard column holders cat no 82000-GH compatible with - FAQ
Read More
Which size guard column should I use with my 1mm Cogent 2.o column - FAQ
Read More
Which solvents should not be used with the Cogent Column Filters - FAQ
Read More
White film developed on my MS source so is this column packing material - FAQ
Read More
Why am I seeing two peaks for quaternium15 Dowicil-75 in LCMS - FAQ
Read More
Why am I seeing two peaks for quaternium-15 or Dowicil-75 in my LCMS data - FAQ
Read More
Why do I see large intermittent pressure spikes in HPLC runs and can it be a defective column - FAQ
Read More
Why you should use temperature control with the UDC-Cholesterol column - Tips & Suggestions
Read More
Will a different guard column hardware system different from the Cogent system affect my results when using a Cogent column - FAQ
Read More
Will using the Cogent Column Filters change my current HPLC results - FAQ
Read More

© Copyright 2025. MICROSOLV. All Rights Reserved. Website & Hosting by BlueTone Media